Pioon laser is always the best & most innovative.
Welcome to the most cutting-edge era of four wavelength laser. With 405nm new laser wavelength and 4-wavelength laser combination, you can fully unleash whole new levels of UTU dental laser potential---starting the most innovative dental laser in your business, your best choice.
Periodontics
Endodontics
LLLT/Photobiomodulation
Aesthetics
Implant
oral surgery
Pedodontics
Prosthodontics
Oral diagnosis
Dental Light Curing
405nm Violet Laser
The primary application of 405nm laser in dentistry focuses on oral diagnosis due to its special ability to induce fluorescence in oral tissue and biomolecules. Oral lesions, abnormalities and dental plaque produced by oral bacteria will exhibit fluorescence under 405nm illumination. Moreover, 405nm violet laser can be used for oral disinfection and root canal treatment, 405nm is a promising alternative method for prevention and/or treatment of endodontic infection.
450nm Blue Laser
450nm blue laser excels in soft tissue cutting/ablation mainly due to its high absorption by hemoglobin and other biological pigments, providing efficient energy transfer and precise cutting. 450nm blue laser significantly reduces bleeding during surgery and minimizes thermal damage to surrounding tissue, making it particularly suitable for precise and minimally invasive medical procedures.
650nm LLLT laser
650nm laser is particularly effective in low-level laser therapy (LLLT), which is utilized to accelerate healing processes, alleviate inflammation, and manage both chronic and acute pain.
980nm Infrared
As a preferred choice for a wide range of dental applications, 980nm is highly effective for cutting and hemostasis, also provides significant antibacterial effects, making it useful in endodontic treatments for sterilizing root canals.
520nm aiming beam
520nm green laser stands out clearly against oral tissues because of the discernible color difference among tissue, blood and aiming beam, enhancing the visibility, and aiding dentists in precision targeting during procedures and compatible with various dental lasers, adding versatility to its use.
- Enhanced visibility: Green lasers are highly visible to the human eye, aiding surgeons in accurately locating and manipulating target tissues during surgery.
- Tissue penetration: The wavelength of green lasers (520nm) allows for deeper tissue penetration, providing clear visualization of deeper structures and facilitating precise anatomical dissection and manipulation.
- Reduced tissue damage: Green lasers have low tissue absorption, which can minimize damage to surrounding tissues during dental surgical procedures, thereby preserving healthy tissue.
- Minimal thermal injury: Green lasers deliver energy more uniformly and can be precisely controlled, reducing the risk of thermal injury during dental surgery and promoting faster postoperative healing.
State-of-the-art Blue Dental Laser
Top-notch design
Better-quality and higher-degree Aluminum-Magnesium alloy case. A more durable frame of better quality and a higher degree of aluminum-magnesium alloy case used in the UTU, the strength, stability, and durability of UTU is now leading the entire medical laser industry as the top 1 medical equipment quality.
NFC fiber identification system
Auto-identifying system control all types of optical fibers connecting with UTU, maintain the consistency and stability of PIOON accessories and equipment and stop the other brand interference and influence.
Protective lens for laser aperture
For maximum equipment safety and extended service life, UTU features a protective lens between the laser module and its laser aperture, reducing the risk of the laser module burning damaged by dust and dirt to less than 5%.
New doctor-focused UI design
Redesigned and re-innovated into a new doctor-focused user interface, long tested and recognized by professional dentists and medical equipment distributors, the new UI design becomes more concise and intuitive, making UTU easier for dentists to use and reducing unnecessary parameters and pattern interference.
Soft starter
UTU innovatively initiates soft starter, greatly optimizing the stability of the software system during equipment power on and off, thereby reducing the software failure rate and prolonging the overall life of the equipment.
Standby mode
After UTU dental handpiece correctly placed, its screen automatically turns off, UTU enters standby mode, which significantly reduces battery consumption and prolongs the battery life of UTU. User picks up the handpiece, and the equipment will immediately resume its working state. Standby mode not only highlights Pioon's ambition for advanced intelligent medical devices, also proves our corporate responsibility of eco-friendly and environmental protection.
Updated AI assistant
With Pioon intelligent software system upgrading into 3.0 version, Pioon AI assistant evolved again, more intelligent, better operation experiences, more humanized assistance, and higher degree human-equipment interaction, Pioon always manufactures the top and the most intelligent medical laser equipment in the whole medical laser industry.
Comfort-focused care
After laser surgery by UTU, the system will remind dentist to start the relaxing and comfortable laser therapy to promote the wound healing and relieve the pain or laser disinfection for patients, bringing the most comfortable and relaxing oral surgery to patients is always Pioon's ultimate pursuit.
Technical Specification
Wavelength and operating performance |
450nm +/-20nm / 7.0W
405nm +/-10 / 500mw 650nm +/-10nm / 500mW 980nm/810nm +/-10nm / 12W/10W |
The wavelength and power of a laser determine its clinical application range |
Laser operating model | Continuous Wave (CW) / Pulse/Super-Pulse | Lasers operating in continuous mode and pulsed mode yield different effects in clinical applications. |
Pulse width | Minimum 10µs, Precise adjustment | Frequency indicates the number of pulses emitted by a laser per second. |
Weight | 2KG NW | Lightweight, facilitating portability. |
Battery Capacity | 3500mAh | Sanyo Lithium-ion batteries provide long-lasting power, ensuring stable operation of the device during extended usage or continuous operation |
Dimensions |
225mm(l)
150mm(w) 150mm(h) |
The compact design does not occupy much space, making it easy to place. |
The medical laser device complies with the following standards
IEC 60601-1:2020 | IEC 62366-1:2020 | ISO 14971:2019 |
IEC 60601-1-2:2020 | IEC 80601-2-60:2019 | ISO 24971:2020 |
IEC 60601-2-22:2019 | IEC 62304:2015 | ISO 10993-1:2018 |
IEC 60825-1:2014 | ISO 15223-1:2021 | ISO 14971:2019 |
Medical-Grade Instruments and Accessories
Handpieces
Photobiostimulation Handpiece
Low-level laser biostimulation can be applied in wound therapy to speed up the wound healing, prevent infection and relieve the pain
LEARN MORETMJ Therapy Handpiece
Primarily used for oral therapy, such as temporomandibular joint (TMJ) therapy, it also includes small-sized TMJ tips for broader and more versatile applications.
LEARN MOREWhitening Handpiece
Used for teeth whitening, it can divide the teeth area into four quadrants, with the whitening head precisely the width of one quadrant.
LEARN MOREMulti-functional Handpiece
A direct connection fiber tip holder compatible with therapy handles, offering excellent compatibility and enabling multifunctional application
LEARN MOREMedical Fibers and Tips
Dental Laser Tip 200μm
The standard version is 15mm, with additional options of 5mm, 15mm, and 25mm tips, along with a 15mm circular tip suitable for root canal disinfection.
LEARN MOREDental Laser Tip 300μm
The standard version is 10mm, with additional options of 5mm, 10mm, 15mm, 50mm, and 100mm tips.
LEARN MOREBare fiber
Bare Fibers(200μm) Length: 3m;Bare Fibers(300μm) Length: 3m;Bare Fibers(400μm) Length: 3m
LEARN MOREDental Laser Tip 400μm
The standard version is 15mm, with additional options of 5mm, 15mm, and 25mm tips, along with a 15mm circular tip suitable for incision, excision, vaporization, ablation, coagulation, as well as soft-tissue curettage and sulcular debridement.
LEARN MOREAccessories
Professional Laser Safety Glasses - Made in Germany (Recommend)
Essential protective gear for laser operations, designed to absorb or reflect specific laser wavelengths effectively, safeguarding the eyes from harm. Compliant with the European Committee for Standardization (CEN) EN 207 standard.
LEARN MOREMultilingual instruction manual
A multilingual instruction manual can enhance user experience, meet regulatory requirements, boost brand image, and improve customer support efficiency.
LEARN MOREMedical-grade Adapter
Compliant with IEC 60601-1, an international standard regarding the safety and performance of medical electrical equipment, ensuring enhanced safety and reliability.
LEARN MOREPacking Box
Packing Box is specifically designed to provide secure and protective storage for diode lasers.
LEARN MOREBare fiber holder
Facilitating the placement and stretching of optical fibers during the laser operation process.
LEARN MORELaser Safety goggles
Essential protective equipment for laser operations, capable of effectively absorbing or reflecting specific wavelengths of laser light to prevent eye injury.
LEARN MOREMedical-grade Plug
Compliant with IEC 60601-1, an international standard regarding the safety and performance of medical electrical equipment, ensuring enhanced safety and reliability.
LEARN MOREBluetooth Medical-grade Foot Pedal (Optional)
Foot pedal, tested for 500,000 cycles, with accompanying test reports, supporting both wired and wireless Bluetooth connectivity.(Optional)
LEARN MOREMedical-grade Foot Pedal (Optional)
Waterproof foot pedal, passing the waterproof test, with a 500,000 times usage test report.(Optional)